Quick Contact


The cables are designed for XDSL transmission system. The cables are characterized by guaranteed data speeds up to 40MHz.
• ER.f5.113
Construction
Solid annealed bare copper sized 0.5mm as per ASTM B-3/IEC 60228 Class1
Solid polyethylene as per ASTM D 1248/IEC 60708
Insulated conductors are twisted into pairs with varying lays to minimize crosstalk
The pairs are cabled together in layers of 12, 13 & 25 pair unit to form the cable core. Units are identified by colour coded binders.
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
An aluminium polyster foil is applied longitudinally with an overlap
Black low density polyethylene as per BS 6234/IEC 60708
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
| Conductor Diameter | mm | 0.5 | 
| Maximum Conductor Resistance @20°C | Ω/km | 91 | 
| Minimum Insulation Resistance @500V DC | MΩ.km | 20000 | 
| Maximum Resistance Unbalance | % | 2 | 
| Average Mutual Capacitance | nF/km | 52 | 
| Maximum Capacitance Unbalance @1KHz pair-to-pair | pF/500m | 45 | 
| Maximum Capacitance Unbalance @1KHz pair-to-ground | pF/500m | 400 | 
| Impedance @0.3 – 1MHz | Ω | 100+/- 20 | 
| Impedance @1 – 40MHz | Ω | 100+/- 15 | 
| Maximum Average Attenuation @0.1MHz | dB/km | 0.81 | 
| Maximum Average Attenuation @0.3MHz | dB/km | 1.15 | 
| Maximum Average Attenuation @0.6MHz | dB/km | 1.65 | 
| Maximum Average Attenuation @1MHz | dB/km | 2.1 | 
| Maximum Average Attenuation @4MHz | dB/km | 4.3 | 
| Maximum Average Attenuation @10MHz | dB/km | 6.6 | 
| Maximum Average Attenuation @16MHz | dB/km | 8.2 | 
| Maximum Average Attenuation @20MHz | dB/km | 9.2 | 
| Maximum Average Attenuation @31.25MHz | dB/km | 11.8 | 
| Maximum Average Attenuation @40MHz | dB/km | 13.9 | 
| Minimum Return Loss @1-20MHz | dB/100m | 23 | 
| Minimum Return Loss @20-40MHz | dB/km | 23-10log (f/20) | 
| Minimum ELFEXT pair-to-pair @0.16MHz | dB | 69 | 
| Minimum ELFEXT pair-to-pair @1MHz | dB | 55 | 
| Minimum ELFEXT pair-to-pair @20MHz | dB | 29 | 
| Minimum ELFEXT pair-to-pair @40MHz | dB | 23 | 
| Minimum NEXT pair-to-pair @0.16MHz | dB | 68 | 
| Minimum NEXT pair-to-pair @1MHz | dB | 59 | 
| Minimum NEXT pair-to-pair @20MHz | dB | 39 | 
| Minimum NEXT pair-to-pair @40MHz | dB | 35 | 
| Dielectric Strength | dB | 
 | 
| Conductor to Conductor 3secs | V DC | 3000 | 
| Conductor to Screen 3secs | V DC | 5000 | 
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C 
Minimum bending radius: 10 x Overall Diameter
Standard colour code is per ANSI/ICEA S-80-576 given in Colour Code Chart.
| Cable Code | Number  | Nominal Insulation  | Nominal Sheath  | Nominal Overall  | Nominal Weight kg/km | 
| 26 | 0.2 | 0.9 | 18.5 | 265 | |
| TP113-2Y(St)Y-51P05-XDSL | 51 | 0.2 | 1.0 | 24.2 | 460 | 
| TP113-2Y(St)Y-101P05-XDSL | 101 | 0.2 | 1.1 | 31.5 | 790 | 
| TP113-2Y(St)Y-202P05-XDSL | 202 | 0.2 | 1.2 | 41.5 | 1415 |