Application

The cables are designed for XDSL transmission system. The cables are characterized by guaranteed data speeds up to 40MHz.

Standards

• ER.f5.113

Construction

Conductors

Solid annealed bare copper sized 0.5mm as per ASTM B-3/IEC 60228 Class1

Insulation

Solid polyethylene as per ASTM D 1248/IEC 60708

Twisted Pairs

Insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Cable Core Assembly

The pairs are cabled together in layers of 12, 13 & 25 pair unit to form the cable core. Units are identified by colour coded binders.

Core Wrapping

One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap

Screen

An aluminium polyster foil is applied longitudinally with an overlap

Sheath

Black low density polyethylene as per BS 6234/IEC 60708

Ripcord

Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical Properties

Conductor Diameter

mm

0.5

Maximum Conductor Resistance @20°C

Ω/km

91

Minimum Insulation Resistance @500V DC

MΩ.km

20000

Maximum Resistance Unbalance

%

2

Average Mutual Capacitance

nF/km

52

Maximum Capacitance Unbalance @1KHz pair-to-pair

pF/500m

45

Maximum Capacitance Unbalance @1KHz pair-to-ground

pF/500m

400

Impedance @0.3 – 1MHz

100+/- 20

Impedance @1 – 40MHz

100+/- 15

Maximum Average Attenuation @0.1MHz

dB/km

0.81

Maximum Average Attenuation @0.3MHz

dB/km

1.15

Maximum Average Attenuation @0.6MHz

dB/km

1.65

Maximum Average Attenuation @1MHz

dB/km

2.1

Maximum Average Attenuation @4MHz

dB/km

4.3

Maximum Average Attenuation @10MHz

dB/km

6.6

Maximum Average Attenuation @16MHz

dB/km

8.2

Maximum Average Attenuation @20MHz

dB/km

9.2

Maximum Average Attenuation @31.25MHz

dB/km

11.8

Maximum Average Attenuation @40MHz

dB/km

13.9

Minimum Return Loss @1-20MHz

dB/100m

23

Minimum Return Loss @20-40MHz

dB/km

23-10log (f/20)

Minimum ELFEXT pair-to-pair @0.16MHz

dB

69

Minimum ELFEXT pair-to-pair @1MHz

dB

55

Minimum ELFEXT pair-to-pair @20MHz

dB

29

Minimum ELFEXT pair-to-pair @40MHz

dB

23

Minimum NEXT pair-to-pair @0.16MHz

dB

68

Minimum NEXT pair-to-pair @1MHz

dB

59

Minimum NEXT pair-to-pair @20MHz

dB

39

Minimum NEXT pair-to-pair @40MHz

dB

35

Dielectric Strength

dB

 

Conductor to Conductor 3secs

V DC

3000

Conductor to Screen 3secs

V DC

5000

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C 
Minimum bending radius: 10 x Overall Diameter

Colour Code

Standard colour code is per ANSI/ICEA S-80-576 given in Colour Code Chart.

Dimensions And Weight

Cable Code

Number 
of 
Pairs/Quads

Nominal Insulation 
Thickness mm

Nominal Sheath 
Thickness mm

Nominal Overall 
Diameter 
mm

Nominal Weight kg/km

TP113-2Y(St)Y-26P05-XDSL

26

0.2

0.9

18.5

265

TP113-2Y(St)Y-51P05-XDSL 51 0.2 1.0 24.2 460
TP113-2Y(St)Y-101P05-XDSL 101 0.2 1.1 31.5 790