Contact Us

+852 2116 1040

+86 180 1862 7191

sales@caledonian-cables.com

Quick Contact

Hot

  • Fire Resistant Cables
  • EN50288-7 Cables
  • Composite Cables
  • EN50288-7 Cables

Certificate

  • Caledonian
  • Caledonian
  • Caledonian
  • Caledonian

Solid PE Insulated & PE Sheathed Jelly Filled Cables to CW 1326 & CW 1326/1179

Application

The cables are designed for use as subscriber distribution cables and as connection between central offices in local access networks.The cables are jelly filled and suitable for installation in ducts. The cables are also available for direct burial in the ground and aerial installation with integral suspension strand. An armoured option is offered for direct burial installations. A figure-8 self support option is offered for aerial installation.

Standards

CW 1326 (For unscreened cable)

CW 1179 (For screened cable)

CW 1252 (For self-supporting cable)

Construction

Conductor : Solid annealed bare copper, 0.5mm as per class 1 of BS6360/IEC 60228.

Insulation : Solid polyethylene as per BS EN50290-2-23/BS6234/IEC 60708.

Twinning : Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk.

Cabling Element : Twisted Pairs.

Cable Core Assembly : Cables are composed of 10-pair units.

Core Wrapping : One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors.

Moisture Barrier (optional) : A layer of aluminium tape (0.15mm) coated with PE-copolymer on one or both sides is applied longitudinally with overlap over the cable core to provide shielding coverage and ensure a barrier against water vapor.

Filling : The cable core interstices are filled with petroleum jelly to avoid longitudinal water penetration within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield, shield and sheath within the cable core.

Sheath : Black low density polyethylene as per BS6234/IEC 60708, being able to withstand exposure to sunlight, temperature variations, ground chemicals and other environmental conditions.

Ripcord : Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal.

Spare Pairs (optional) : Spare pairs may be incorporated for 200 and larger pair cables.

Continuity Wire (optional) : Tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen.

Electrical Properties

Nominal Conductor Diameter mm 0.5
Conductor Gauge Size AWG 24
Conductor Size mm² 0.196
Maximum Average Conductor Resistance @20°C Ω/km 91
Minimum Insulation Resistance @500V DC MΩ.km 1500
Maximum Average Mutual Capacitance @800Hz* nF/km 56
Maximum Individual Mutual Capacitance @800Hz (for 99% cases) nF/km 64
Maximum Individual Capacitance Unbalance @800Hz pair-to-pair pF/500m 275
Maximum Conductor Loop Resistance @20°C Ω/km 192
Impedance @1KHz 796
Impedance @100KHz 134
Impedance @512KHz 118
Impedance @1MHz 115
Maximum Average Attenuation @0.8KHz dB/km 1.30
Maximum Average Attenuation @1KHz dB/km 1.35
Maximum Average Attenuation @3KHz dB/km 2.52
Maximum Average Attenuation @150KHz dB/km 8.3
Maximum Average Attenuation @772KHz dB/km 19.4
Maximum Average Attenuation @1000KHz dB/km 21.4
Dielectric Strength Conductor to Conductor (3secs) V DC 500
Nominal Insulation Thickness mm 0.275
Nominal Insulated Conductor Diameter mm 1.05

*For screened cables of 20 pairs or less, the maximum average mutual capacitance shall not apply and the maximum for 99% of cases shall be increased by 3nF

Mechanical and Thermal Properties

Temperature during operation : -30°C – +70°C

Temperature during installation : -20°C – +50°C

Bending radius : 10 x Overall Diameter

Colour Code

Standard colour code is per CW1326 given in the following Colour Code Chart

Pair Number Tip Colour Ring Colour Pair Number Tip Colour Ring Colour
1 WHITE BLUE 13 BLACK GREEN
2 WHITE ORANGE 14 BLACK BROWN
3 WHITE GREEN 15 BLACK GREY
4 WHITE BROWN 16 YELLOW BLUE
5 WHITE GREY 17 YELLOW ORANGE
6 RED BLUE 18 YELLOW GREEN
7 RED ORANGE 19 YELLOW BROWN
8 RED GREEN 20 YELLOW GREY
9 RED BROWN 21 VIOLET BLUE
10 RED GREY 22 VIOLET ORANGE
11 BLACK BLUE 23 VIOLET GREEN
12 BLACK ORANGE 24 VIOLET BROWN
      25 VIOLET GREY

Units binders

No. of Units Binder Colour No. of Units Binder Colour
1 BLUE 6 WHITE
2 ORANGE 7 RED
3 GREEN 8 BLACK
4 BROWN 9 YELLOW
5 GREY 10 VIOLET

Dimensions And Weight

Solid PE Insulated and Unscreened/Screened PE Sheathed Jelly Filled Cable to CW 1326, CW 1326/1179

Cable Code Number of Pairs Minimum Sheath Thickness Maximum Overall Diameter (Unscreened) Nominal Weight (Unscreened) Maximum Overall Diameter (Screened) Nominal Weight (Screened)
    mm mm kg/km mm kg/km
0.5mm Conductor, 1.05mm Insulated Wire
TP1326-2YF(L)2Y-2P05 2 1.1 8.5 55 10.0 65
TP1326-2YF(L)2Y-5P05 5 1.2 8.5 77 10.0 87
TP1326-2YF(L)2Y-10P05 10 1.2 12.0 126 13.5 137
TP1326-2YF(L)2Y-20P05 20 1.3 15.0 221 16.5 231
TP1326-2YF(L)2Y-30P05 30 1.4 18.0 332 19.5 347
TP1326-2YF(L)2Y-50P05 50 1.4 19.5 483 21.0 504
TP1326-2YF(L)2Y-100P05 100 1.5 25.0 933 26.5 956

*The above part number will be changed for unscreened cables by deleting the (L).

Solid PE Insulated, PE Inner Sheathed, Steel Wire Armoured and PE Outer Sheathed Jelly Filled Cable to CW 1326/1198 (Unscreened)

Cable Code Number of Pairs Minimum Bedding Thickness Steel Wire Diameter Minimum Sheath Thickness Maximum Overall Diameter Nominal Weight
    mm mm mm mm kg/km
0.5mm Conductor, 1.05mm Insulated Wire
TP1326-2YF2Y(SWA)2Y-2P05 2 1.1 0.9 0.9 13.7 241
TP1326-2YF2Y(SWA)2Y-5P05 5 1.2 0.9 0.9 13.7 274
TP1326-2YF2Y(SWA)2Y-10P05 10 1.2 0.9 0.9 17.2 351
TP1326-2YF2Y(SWA)2Y-20P05 20 1.3 1.25 0.9 20.9 499
TP1326-2YF2Y(SWA)2Y-30P05 30 1.4 2.0 1.0 24.8 749
TP1326-2YF2Y(SWA)2Y-50P05 50 1.4 2.0 1.0 26.3 1123
TP1326-2YF2Y(SWA)2Y-100P05 100 1.5 2.0 1.1 32.0 1763

Solid PE Insulated, PE Inner Sheathed, Steel Wire Armoured and PE Outer Sheathed Jelly Filled Cable to CW 1326/1179/1198 (Screened)

Cable Code Number of Pairs Minimum Bedding Thickness Steel Wire Diameter Minimum Sheath Thickness Maximum Overall Diameter Nominal Weight
    mm mm mm mm kg/km
0.5mm Conductor, 1.05mm Insulated Wire
TP1326-2YF(L)2Y(SWA)2Y-2P05 2 1.1 0.9 0.9 15.2 251
TP1326-2YF(L)2Y(SWA)2Y-5P05 5 1.2 0.9 0.9 15.2 286
TP1326-2YF(L)2Y(SWA)2Y-10P05 10 1.2 1.25 0.9 19.4 363
TP1326-2YF(L)2Y(SWA)2Y-20P05 20 1.3 2.0 1.0 23.3 501
TP1326-2YF(L)2Y(SWA)2Y-30P05 30 1.4 2.0 1.0 26.3 752
TP1326-2YF(L)2Y(SWA)2Y-50P05 50 1.4 2.0 1.1 28.0 1139
TP1326-2YF(L)2Y(SWA)2Y-100P05 100 1.5 2.0 1.2 30.5 1786