Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
| Conductor |
Tinned annealed copper wires as defined in EN 50306-2 |
| Insulation |
LSZH special compound |
| Pair Identification |
Pairs numbered according to EN 50306-4 |
| Overal Screen |
Tinned annealed copper wires |
| Outer Sheath |
LSZH special compound (S2, EM 101 - EM 104) |
Electrical & Mechanical Properties
| Nominal Voltage |
300/500 V |
| Max. Conductor Temperature |
90°C /105°C (fixed installation) |
| Min. Permissible Ambient Temperature |
-25°C/-40°C (fixed installation) |
| Bending Radius |
10 x Overall Diameter |
Chemical & Environmental Propertie
| EN 60684-2 |
No fluorine |
| EN 50305; EN 60811-2-1 |
Resistance to mineral oil & fuel oil, acid & alkali |
| EN 50305 |
Resistance to ozone |
Fire Performance for rolling stock application
| EN 50306-2 |
Hazard levels HL1, HL2, HL3 |
| DIN 5510-2 |
Protection level 1/2/3/4 |
| BS 6853 |
Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
| NF F 16-101 |
F0 |
| EN54454-2 |
R15 Interior/ R16 Exterior HL1, HL2, HL3 |
Fire Performance in General
| EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) |
Vertical flame propogation for a single insulated wire or cable |
| EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
| EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
| EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 |
Halogen Free |
| EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 |
Low Corrosivity (Acidity & Conductivity) |
| EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 |
Low Toxicity |
| NF F 63 808; BS6853; NF F 16 101 |
Smoke index |
| EN45545-2 |
Requirement for fire behavior of materials & components R15/R16 |
FRL-TW-05MP-ESW-OS 300/500 V