RG6 Armoured Coaxial Cable

Applications

These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.

Standards

IEC 60092-350

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2016

Construction

Conductors : 18AWG solid bare copper.

Insulation : Foam PE.

Shielding1 : Al/Polyester/Al tape.

Shielding2 : Tinned copper braid.

Bedding : Low smoke and halogen-free polyolefin, coloured black.

Armour : Tinned copper wire braid.

Outer Sheath : Low smoke and halogen-free polyolefin.

Electrical Characteristics

AWG   18
Nominal Conductor Diameter mm 1.0
Impedance Ω 75+/-5
Nominal Attenuation@100MHz dB/100m 6.9
Nominal Attenuation@200MHz dB/100m 9.0
Nominal Attenuation@300MHz dB/100m 11.8
Nominal Attenuation@400MHz dB/100m 13.1
Nominal Attenuation@500MHz dB/100m 15.4
Nominal Attenuation@900MHz dB/100m 21.5
Nominal Attenuation@1700MHz dB/100m 29.4
Capacitance pF/m 53.5
Velocity of Propagation % 83
Conductor DCR Ω/km 21.4
Shield DCR Ω/km 7.5
Inductance μH/m 0.32
Time Delay ns/m 4

Mechanical and Thermal Properties

Bending Radius : 15×OD

Temperature Range : -30℃ ~ +75℃

Dimensions and Weight

Nominal Inner Conductor Diameter Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Nominal Weight
mm mm mm mm kg/km
1.0 1.8 1.2 11.2 208