    EPR/Copper Tape Shield with Overall LSZH Jacket Uniblend Medium-Voltage Power, Shielded, 15KV, UL Type MV-105 133% Ins. Level, 220 Mils, Three Conductor

    Applications

    These cables are suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical. Besides, they are installed in wet or dry locations accordance with NEC. Also in aerial, direct burial, conduit, open tray and underground duct installations.

    Standard

    National Electrical Code (NEC)

    UL 1072

    ICEA S-93-639/NEMA WC74

    ICEA S-97-682

    AEIC CS8

    UL 1685 (70,000 BTU/hr)

    Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method

    Optional Flame Tests :

    IEEE 1202 (70,000 BTU/hr)/CSA FT4

    ICEA T-29-520 (210,000 BTU/hr)

    Construction

    Conductor : Annealed bare copper Class B strand.

    Extruded Strand Shield (ESS) : Extruded thermoset semi-conducting stress-control layer over conductor.

    Insulation : Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting shield layers.

    Extruded Insulation Shield (EIS) : Thermoset semi-conducting polymeric layer free stripping from insulation.

    Metallic Shield : 5 mil annealed copper tape with an overlap of 25%.

    Grounding Conductor : 1 bare grounding conductor may be in contact with metallic shielding tape.

    Overall Jacket : Flame-retardant Polyvinyl Chloride (LSZH), UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

    Cables Parameter

    CON. Size Nominal CON. Diameter Insulation Diameter Nominal Jacket Thickness Appr. Cable O.D. Appr. Cable Weight Ampacity
    AWG/kcmil Inches mm Min. Max. Inches mm Inches mm LBS/1000FT kg/km In Air GND. Direct Burial
    Inches mm Inches mm
    2 0.27 6.86 0.710 18.03 0.800 20.32 0.110 2.79 2.04 51.82 2226 3313 165 160 185
    1/0 0.34 8.89 0.780 19.81 0.865 21.97 0.110 2.79 2.20 55.88 2811 4183 215 210 240
    2/0 0.38 9.65 0.820 20.83 0.905 22.99 0.110 2.79 2.30 58.42 3163 4707 245 235 275
    4/0 0.48 12.19 0.920 23.37 1.005 25.53 0.110 2.79 2.52 64.01 4203 6255 320 305 360
    250 0.53 13.46 0.970 24.64 1.060 26.92 0.110 2.79 2.66 67.56 4775 7106 350 335 400
    350 0.62 15.75 1.070 27.18 1.155 29.34 0.110 2.79 2.94 74.68 6182 9200 430 400 490
    500 0.74 18.80 1.190 30.23 1.275 32.39 0.140 3.56 3.21 81.53 7686 11438 525 485 600
    750 0.91 23.11 1.370 34.80 1.460 37.08 0.140 3.56 3.61 91.69 10978 16337 635 585 745
    1000 1.06 26.92 1.520 38.61 1.610 40.89 0.140 3.56 3.99 101.35 13983 20810 725 660 860