Contact Us

+852 2116 1040

+86 180 1862 7191

sales@caledonian-cables.com

Quick Contact

Hot

  • Fire Resistant Cables
  • EN50288-7 Cables
  • Composite Cables
  • EN50288-7 Cables

Certificate

  • Caledonian
  • Caledonian
  • Caledonian
  • Caledonian
  • Caledonian

Join the newsletter

Subscribe to get our latest content by email.

    We won't send you spam.

    Unsubscribe at any time.

    EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded 5KV and 8KV, UL Type MV-105, 133% / 100% Ins. Levels, 115 Mils

    Applications

    These cables are suitable for use in wet or dry locations when installed in accordance with NEC, use in aerial, conduit, open tray and underground duct installations and use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4 (A) (5). Besides, they are installed in a broad range of commercial, industrial and utility projects such as pulp and paper mills, petrochemical plants, steel mills, textile mills, water and sewage treatment facilities, environmental protection systems, railroads, mines and fossil fuel utility generating stations.

    Standard

    National Electrical Code (NEC)

    UL 1072

    ICEA S-93-639/NEMA WC74

    ICEA S-97-682

    AEIC CS8

    UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test

    IEEE 1202 (70,000 BTU/hr)/CSA FT4

    Meets EPA 40 CFR, Part 2671 for leachable lead content per TCLP method

    Optional Flame Tests :

    ICEA T-29-520 (210,000 BTU/hr)

    Construction

    Conductor : Annealed bare copper Class B strand.

    Extruded Strand Shield (ESS) : Extruded thermoset semi-conducting stress-control layer over conductor.

    Insulation : Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black conducting Shield layers.

    Extruded Insulation Shield (EIS) : Thermoset semi-conducting polymeric layer free stripping from insulation.

    Metallic Shield : 5 mil annealed copper tape with an overlap of 25%.

    Jacket : Flame-retardant, moisture- and sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH).

    Cables Parameter

    CON. Size Nominal CON. Diameter Insulation Diameter Nominal Jacket Thickness Appr. Cable O.D. Appr. Cable Weight Ampacity
    AWG/kcmil Inches mm Min. Max. Inches mm Inches mm LBS/1000 FT kg/km In Air GND.
    Inches mm Inches mm
    6 0.17 4.32 0.415 10.54 0.490 12.45 0.060 1.52 0.65 16.51 295 439 93 97
    4 0.22 5.39 0.455 11.56 0.535 13.59 0.060 1.52 0.70 17.15 365 543 120 125
    2 0.27 6.86 0.510 12.95 0.590 14.99 0.060 1.52 0.76 19.05 471 701 165 165
    1 0.31 7.87 0.545 13.84 0.620 15.75 0.060 1.52 0.79 20.07 539 802 190 185
    1/0 0.34 8.89 0.580 14.73 0.655 16.64 0.060 1.52 0.82 21.08 623 927 215 215
    2/0 0.38 9.65 0.620 15.75 0.695 17.65 0.060 1.52 0.86 22.10 728 1083 255 245
    3/0 0.43 10.92 0.665 16.89 0.745 18.92 0.080 2.03 0.94 24.38 886 1318 290 275
    4/0 0.48 12.19 0.720 18.29 0.795 20.19 0.080 2.03 1.00 25.65 1053 1567 330 315
    250 0.53 13.46 0.770 19.56 0.850 21.59 0.080 2.03 1.05 27.18 1199 1784 365 345
    350 0.62 15.75 0.870 22.10 0.945 24.00 0.080 2.03 1.14 29.72 1559 2320 440 415
    500 0.74 18.80 0.990 25.15 1.065 27.05 0.080 2.03 1.27 33.53 2088 3107 535 500
    750 0.91 23.11 1.170 29.72 1.250 31.75 0.080 2.03 1.45 38.35 2962 4407 655 610
    1000 1.06 26.92 1.330 33.78 1.400 35.56 0.080 2.03 1.60 42.42 3815 5677 755 690
    Contact Us

    Add the link of current page.

    Clear

    Submit

    Instant Messaging

    WhatsApp :

    +852 6230 0392

    Skype :

    Caledonian Cables

    live:1cb87739a29fb08c

    Wechat :
    The personal information you enter is only used to reply to your message, It will not be leaked or used for other purposes.