| Parameter | 50/125 | 62.5/125 | Units | ||
| Fiber Code | 5 | 4 | 6 | - | |
| ISO/IEC 11801 Classifi cation(2)O | - | ||||
| Attenuation, Loose Tube Cables | |||||
| @850nm | ≤3.0 | ≤3.0 | dB/km | ||
| @1300nm | ≤0.8 | ≤0.8 | dB/km | ||
| Attenuation, Tight Buffer and Semi-tight Cables | |||||
| @850nm | ≤3.0 | ≤3.5 | dB/km | ||
| @1300nm | ≤1.0 | ≤1.0 | dB/km | ||
| Bandwidth﹡ | @850nm | ≥500 | ≥2000 | ≥200 | MHz*km |
| @1300nm | ≥800/500 | ≥500 | ≥500/600 | MHz*km | |
| Numerical Aperture | 0.20±0.015 | 0.275±0.015 | - | ||
| Core Diameter | 50±3 | 62.5±3 | um | ||
| Cladding Diameter | 125±2 | 125±2 | um | ||
| Core/Cladding Concentricity | ≤1.5 | ≤1.5 | um | ||
| Core Non-Circularity | ≤6 | ≤6 | % | ||
| Cladding Non-Circularity | ≤2 1 | ≤2 1 | % | ||
| Core/Cladding Offset | ≤3 | ≤3 | um | ||
| Coating Diameter | 245±10 | 245±10 | um | ||
| Proof-Test Level | 100 (0.7) | 100 (0.7) | Kpsi (GN/m2) | ||
| Fatigue Coeffi cient | ≥20 | ≥20 | |||
| Temperature Dependence between 0℃ - 70℃ | 0.1 | 0.1 | dB | ||