Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Bus Cables

Bus Cables

E-Bus Cables

Application: These cables are used for the transmission of bus signals in buildings, where intelligent system are used. The EIB bus can be used to control lighting, blinds, heating, ventilation, indicator boards, etc. This cables can maintain perfect communicationaccording to EIB regulations (European installation bus).

2 Pairs 4 Core FRNC & PVC E-Bus Cables

2 Pairs 4 Core PE E-Bus Cables

4 Pairs 4 Core PVC E-Bus Cables

 

2 Pairs 4 Core FRNC & PVC E-Bus Cables

Conductor: Bare Copper

Insulation: PVC

Conductor Colour: White, Yellow, Red, Black

Stranding: Star quad

Shielding: Polyester foil over stranded bundle

Total Shielding: Polyester foil, aluminum-lined

Sheath/Jacket: PVC

Colour: Blue, Green

Drain Wire: Yes

Outer Cable Diameter: 6.6 mm ± 0.3 mm

Operating temperature: - 30 °C to +70°C

Standards: EIB Standard

Size (Type)

Characteristic Impedance
Conductor Resistance
Insulation Resistance
Mutual Capacitance
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 2 X 0.8mm2 (Blue)

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
95.0 mm
0.90 MJ/m
Approx. 54.0 kg/km

2 X 2 X 0.8mm2 (Green)

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
95.0 mm
0.90 MJ/m
Approx. 54.0 kg/km

 

2 Pairs 4 Core PE E-Bus Cables

Conductor: Bare Copper

Insulation: PE

Conductor Colour: White, Yellow, Red, Black

Stranding: Star quad

Shielding: Polyester foil over stranded bundle

Total Shielding: Polyester foil, aluminum-lined

Sheath/Jacket: FRNC

Colour: Blue

Drain Wire: Yes

Outer Cable Diameter: 6.6 mm ± 0.3 mm

Operating temperature: - 30 °C to +70°C

Standards: EIB Standard

Size (Type)

Characteristic Impedance
Conductor Resistance
Insulation Resistance
Mutual Capacitance
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 2 X 0.8mm2

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
95.0 mm
0.58 MJ/m
Approx. 54.0 kg/km

 

4 Pairs 4 Core PVC E-Bus Cables

Conductor: Bare Copper

Insulation: PVC

Conductor Colour: White, Yellow, Red, Greed, Blue, Brown, White, White

Stranding: Double Conductor

Shielding: Polyester foil over stranded bundle

Total Shielding: Polyester foil, aluminum-lined

Sheath/Jacket: PVC

Colour: Blue

Drain Wire: Yes

Outer Cable Diameter: 8.3 mm ± 0.4 mm

Operating temperature: - 30 °C to +70°C

Standards: EIB Standard

Size (Type)

Characteristic Impedance
Conductor Resistance
Insulation Resistance
Mutual Capacitance
Min. Bending Radius
Caloric Load, approx. value
Weight

4 X 2 X 0.8mm2

100 Ohm
73.2 Ohm/km
0.10 GOhm x km Min.
100.0 nF/km Nom.
120.0 mm
1.37 MJ/m
Approx. 92.0 kg/km