Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Bus Cables

Bus Cables

ASI Cables

Application: The ASI is the field bus system that transmits both data and power in one single cable. With fast contacting in penetration technique, it can largely reduce the possibility of errors in cabling. Different jacket can provide protection against oils, grease, and refrigerant lubricants.

ASI EPDM Cables

ASI PUR Cables

ASI PVC Cables

 

ASI EPDM Cables

Conductor: Tinned Copper

Insulation: Rubber Compound

Conductor Colour: Blue, Brown

Sheath/Jacket: EPDM

Colour: Yellow / Black

Operating temperature: - 40 °C to +85 °C

Standards: ASI Standard

Size (Type)

Conductor Resistance
Insulation Resistance
Nominal Voltage
Testing Voltage
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 1.5mm2 (Yellow)

13.7 Ohm/km
1.00 GOhm x km Min.
32 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 70.0 kg/km

2 X 1.5mm2 (Black)

13.7 Ohm/km
1.00 GOhm x km Min.
48 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 70.0 kg/km

 

ASI PUR Cables

Conductor: Tinned Copper

Insulation: Rubber Compound

Conductor Colour: Blue, Brown

Sheath/Jacket: PUR

Colour: Yellow / Black

Operating temperature: - 40 °C to +85 °C

Standards: ASI Standard

Size (Type)

Conductor Resistance
Insulation Resistance
Nominal Voltage
Testing Voltage
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 1.5mm2 (Yellow)

13.7 Ohm/km
1.00 GOhm x km Min.
32 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 64.0 kg/km

2 X 1.5mm2 (Black)

13.7 Ohm/km
1.00 GOhm x km Min.
48 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 64.0 kg/km

 

ASI PVC Cable

Conductor: Tinned Copper

Insulation: TPE

Conductor Colour: Blue, Brown

Sheath/Jacket: PVC

Colour: Yellow / Black

Operating temperature: - 40 °C to +105 °C

Standards: ASI Standard

UL Style: CMG 90°C or CL2

CSA Standard: CSA FT4

Size (Type)

Conductor Resistance
Insulation Resistance
Nominal Voltage
Testing Voltage
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 1.5mm2 (Yellow)

13.7 Ohm/km
1.00 GOhm x km Min.
32 V
1.0 kV @ 15 min.
24.0 mm
0.66 MJ/m
Approx. 70.0 kg/km

2 X 1.5mm2 (Black)

13.7 Ohm/km
1.00 GOhm x km Min.
48 V
1.0 kV @ 15 min.
24.0 mm
0.65 MJ/m
Approx. 70.0 kg/km