Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
Cavo per Materiale Rotabile

Cavo per Materiale Rotabile

    RSE/STD/024 PART 6

      RSE/STD/024 Part 6 Rolling Stock Cable

600/1000V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅲ Cable ,unsheathed

Cross- sectional Area

50mm2-185mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Enhanced Wall

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter (mm)

Nominal Weight (kg/km)

singlecore

50.0

396/0.4

600/1000

16.45

667.0

singlecore

70.0

360/0.5

600/1000

18.35

873.0

singlecore

95.0

475/0.6

600/1000

19.5

1108.0

singlecore

150.0

756/0.5

600/1000

24.1

1663.0

singlecore

185.0

925/0.5

600/1000

26.5

2024.0

600/1000V Multicore RSE/STD/024 Part 6 Rolling Stock Type Ⅵ Cable, with jacket

Cross- sectional Area

2.5mm2-4mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

10-20

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Standard Wall

Jacket

Cross linked EVA rubber type EM 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

10 Core

2.5

50/0.25

600/1000

28.1

1148.0

20 Core

4.0

56/0.3

600/1000

42.7

2421.0

 600/1000V Singlepair RSE/STD/024 Part 6 Rolling Stock Type Ⅹscreened Cable, with jacket 

Cross- sectional Area

1.0mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

37 AWG stranding

Insulation

Cross linked EPR rubber type EI 107, Reduced Wall

Screen

Copper Braid Screen

Jacket

Cross linked EVA rubber type EM 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight (kg/km)

1 Pair

1.0

37/0.18

600/1000

7.3

76.4

                                                                        1       2       3