    Type SHD-GC Three-Conductor Round Portable Power Cable, TPU Jacket 2kV

    • Type SHD-GC Three-Conductor Round Portable Power Cable, TPU Jacket 2kV

    Application

    These heavy duty cables are designed for heavy mobile equipment such as drag lines, shovels, dredges, drills and for power feeders.

    Standards

    • ICEA S-75-381/NEMA WC 58
    • ASTM B 172
    • ASTM B 33
    • CAN/CSA C22.2 No. 96

    Construction

    Conductors Stranded annealed tinned copper conductor.
    Insulation Ethylene Propylene Rubber (EPR).
    Insulation Shield Tinned copper/textile braid.
    Ground Check Conductor Tinned copper conductor with a yellow polypropylene insulation.
    Grounding Conductor Tinned copper conductor.
    Jacket Thermoplastic Polyurethane (TPU) Jacket, black.

    Options

    Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
    Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

    Mechanical and Thermal Properties

    Minimum Bending Radius 6×OD
    Maximum Conductor Operating Temperature +90℃

    Dimensions and Weight

    Construction No. of Strands Grounding Conductor Size Ground Check Conductor Size Nominal Insulation Thickness Nominal Jacket Thickness Nominal Overall Diameter Height×Width Nominal Weight Ampacity
    No. of cores × AWG/kcmil - AWG/kcmil AWG/kcmil inch mm inch mm inch mm lbs/kft kg/km A
    3×6 133 10 10 0.07 1.8 0.155 3.9 1.29 32.8 1069 1590 93
    3×4 259 8 10 0.07 1.8 0.155 3.9 1.40 35.6 1295 1927 122
    3×2 259 6 10 0.07 1.8 0.170 4.3 1.59 40.4 1778 2645 159
    3×1 259 5 8 0.08 2.0 0.190 4.8 1.76 44.7 2163 3218 184
    3×1/0 266 4 8 0.08 2.0 0.190 4.8 1.86 47.2 2508 3731 211
    3×2/0 323 3 8 0.08 2.0 0.205 5.2 2.00 50.8 3001 4465 243
    3×3/0 418 2 8 0.08 2.0 0.205 5.2 2.13 54.1 3470 5163 279
    3×4/0 532 1 8 0.08 2.0 0.220 5.6 2.31 58.7 4192 6237 321
    3×250 627 1/0 6 0.095 2.4 0.220 5.6 2.51 63.8 5213 7756 355
    3×350 888 2/0 6 0.095 2.4 0.235 6.0 2.81 71.4 6824 10153 435
    3×500 1221 4/0 6 0.095 2.4 0.265 6.7 3.19 81.0 9014 13411 536

    Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.