Quick Contact
These cables are designed for fixed installation in electrial power and control systems below and above deck, preferably on ships of the German Navy and/or German design of construction. Not intended for permanent installation in or under water. Fulfill all requirements of BV3400 (Specification for Construction of German Navy vessels).
VG 95218-66
VG 95218-2
IEC 60228
VDE 0207-22
Conductor : Tinned copper conductor
Insulation : Crosslinked polyethylene blend
Triple Screen : Tinned copper wire braided screen
Separator : Halogen free plastic foil
Overall Screen : Tinned copper wire braided screen, separator tape, two screens electricaly separated
Sheath : Crosslinked elastomer compound, black
The cores are to be marked by coloring the insulation or its surface. The triples shall have colored separators C or colored stripes
Core in each triple : Black, White, Grey
Triple marking :
In each layer :
1 Triple : Red
2 Triple : Green
3 Triple : Nature
Pilot and direction shall be the same in all layers.
Nominal voltage : 250V
Max. operating voltage : AC 250V, DC 355V
Operating temperature at conductor : + 85°C
Number of cores and nominal cross section | Nominal diameter of conductor | Nominal insulation thickness | Nominal sheath thickness | Outer diameters | Approx. cable weight | |
---|---|---|---|---|---|---|
min. | max. | |||||
mm² | mm | mm | mm | mm | kg/km | |
5x3x0.4 | 0.85 | 0.2 | 1.0 | 12.2 | 13.9 | 328 |
12x3x0.4 | 0.85 | 0.2 | 1.2 | 16.9 | 18.9 | 613 |