These cables are designed for fixed installation in electrial power and control systems below and above deck, preferably on ships of the German Navy and/or German design of construction. Not intended for permanent installation in or under water. Fulfill all requirements of BV3400 (Specification for Construction of German Navy vessels).
VG 95218-65
VG 95218-2
IEC 60228
VDE 0207-22
Conductor : Tinned copper conductor
Insulation : Halogen free, cross linked polyethylene blend
Pair Screen : Tinned copper wire braided screen, separator tape (optional)
Separator : Halogen free plastic foil
Overall Screen : Tinned copper wire braided screen, separator tape (optional)
Sheath : Crosslinked elastomer compound, black
1Pair : Black, Blue (Pilot pair)
2Pair : Black, Brown (Direction pair)
3Pair and others : Black, Grey
Pilot and direction shall be the same in all layers
Cores in each pair : Black, White
1Pair with 1.2mm² : Red
2Pair with 1.2mm² : Green
3Pair with 1.2mm² : Nature
In each layer :
1Pair with 0.25mm² : Red
2Pair with 0.25mm² : Green
3Pair with 1.2mm² : Nature
1Quad : Black, white, grey blue, filler strip : red (Pilot quad)
2Quad : Black, white, grey blue, filler strip : red (Direction quad)
3Quad and others : Black, white, grey blue
Pilot and direction shall be the same in all layers.
Nominal voltage : 250V
Max. operating voltage : AC 250V, DC 355V
Operating temperature at conductor : + 85°C
Number of cores and nominal cross section | Nominal diameter of conductor | Nominal insulation thickness | Nominal sheath thickness | Outer diameters | Approx. cable weight | |
---|---|---|---|---|---|---|
min. | max. | |||||
mm² | mm | mm | mm | mm | kg/km | |
2x2x0.4 | 0.85 | 0.2 | 0.8 | 9.3 | 10.3 | 140 |
4x2x0.4 | 0.85 | 0.2 | 0.8 | 10.0 | 11.3 | 195 |
7x2x0.4 | 0.85 | 0.2 | 0.9 | 12.0 | 13.5 | 290 |
12x2x0.4 | 0.85 | 0.2 | 1.0 | 15.5 | 17.0 | 460 |
19x2x0.4 | 0.85 | 0.2 | 1.0 | 18.4 | 20.4 | 650 |
27x2x0.4 | 0.85 | 0.2 | 1.1 | 22.5 | 24.5 | 920 |
Number of cores and nominal cross section | Nominal diameter of conductor | Nominal insulation thickness | Nominal sheath thickness | Outer diameters | Approx. cable weight | |
---|---|---|---|---|---|---|
min. | max. | |||||
mm² | mm | mm | mm | mm | kg/km | |
3x2x1.2 | 1.5 | 0.25 | 1.2 | 20.0 | 21.2 | 750 |
18x2x0.25 | 0.65 | 0.2 | 1.2 | 20.0 | 22.2 | 750 |
Number of cores and nominal cross section | Nominal diameter of conductor | Nominal insulation thickness | Nominal sheath thickness | Outer diameters | Approx. cable weight | |
---|---|---|---|---|---|---|
min. | max. | |||||
mm² | mm | mm | mm | mm | kg/km | |
27x4x0.25 | 0.21 | 0.2 | 1.2 | 22.0 | 26.0 | 1000 |