Quick Contact
These cables are designed for fixed installation in electrial power and control systems below and above deck, preferably on ships of the German Navy and/or German design of construction. Not intended for permanent installation in or under water. Fulfill all requirements of BV3400 (Specification for Construction of German Navy vessels).
VG 95218-64
VG 95218-2
IEC 60228
VDE 0207-22
Conductor : Tinned copper conductor
Insulation : Halogen free, cross linked polyethylene blend
Separator : Halogen free plastic foil.
Overall Screen : Tinned copper wire braided screen, separator tape-two sreens electricaly seperated (type LFMGSGO – single screen)
Sheath : Crosslinked elastomer compound, black
Back, Blue, Grey, Grown
1 pair : Black, Blue (pilot pair)
2 pair : Black, Brown (direction pair)
3 pair and others : Black, Grey
Pilot and direction shall be the same in all layers.
Nominal voltage : 250V
Max. operating voltage : AC 250V, DC 355V
Operating temperature at conductor : + 85°C
Number of cores and nominal cross section | Nominal diameter of conductor | Nominal insulation thickness | Nominal sheath thickness | Outer diameters | Approx. cable weight | |
---|---|---|---|---|---|---|
min. | max. | |||||
mm² | mm | mm | mm | mm | kg/km | |
2x2x0.4 | 0.85 | 0.2 | 0.8 | 5.8 | 6.8 | 80 |
4x2x0.4 | 0.85 | 0.2 | 0.8 | 7.7 | 8.7 | 130 |
7x2x0.4 | 0.85 | 0.2 | 0.9 | 9.4 | 10.8 | 210 |
12x2x0.4 | 0.85 | 0.2 | 1.0 | 12.8 | 13.8 | 320 |
19x2x0.4 | 0.85 | 0.2 | 1.0 | 13.8 | 15.5 | 420 |
27x2x0.4 | 0.85 | 0.2 | 1.1 | 15.5 | 17.3 | 511 |
Number of cores and nominal cross section | Nominal diameter of conductor | Nominal insulation thickness | Nominal sheath thickness | Outer diameters | Approx. cable weight | |
---|---|---|---|---|---|---|
min. | max. | |||||
mm² | mm | mm | mm | mm | kg/km | |
30x2x0.4 | 0.85 | 0.2 | 1.4 | 17.5 | 18.7 | 471 |
45x2x0.4 | 0.85 | 0.2 | 1.6 | 20.6 | 22.5 | 660 |
60x2x0.4 | 0.55 | 0.3 | 1.6 | 22.4 | 23.0 | 767 |