These FEP/polyimide/FEP tape insulated single-core M81381/8 cables are used in aerospace applications and other challenging applications. It is well-suited to applications concerned with smoke emission and overload stability.
Conductor | Stranded nickel-plated copper conductor |
Insulation | FEP/polyimide/FEP tape insulation |
Insulation Wall Thickness | 0.0065” |
Jacket | modified aromatic polyimide coating |
Temperature Range | -55°C + 200°C |
Voltage Rating | 600 volts |
Color Code | MIL-STD-104 (See page 42 ) 10 basic colors(BLK,BRN,RED,ORN,YEL,GRN,BLU,VIO,GRY,WHT) |
AWG SIZE | CONDUCTOR STRANDING | CONDUCTOR DIAM.?MAX. | CONDUCTOR DIAM.?MIN. | MAX. O.D. | MIN. O.D. | MAXIMUM RESISTANCE (OHM/1000' @ 20°C) | APPROX LBS/MFT | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
? | ? | IN | MM | IN | MM | IN | MM | IN | MM | ? | ? |
26 | 19/38 | 0.020 | 0.510 | 0.018 | 0.460 | 0.031 | 0.870 | 0.030 | 0.787 | 42.20 | 1.2 |
24 | 19/36 | 0.024 | 0.610 | 0.023 | 0.580 | 0.034 | 0.864 | 0.034 | 0.864 | 25.90 | 1.8 |
22 | 19/34 | 0.031 | 0.790 | 0.029 | 0.740 | 0.041 | 1.041 | 0.041 | 1.041 | 16.00 | 2.7 |
20 | 19/32 | 0.039 | 0.930 | 0.037 | 0.940 | 0.049 | 1.245 | 0.049 | 1.245 | 9.77 | 4.2 |
18 | 19/30 | 0.049 | 1.240 | 0.046 | 1.170 | 0.059 | 1.499 | 0.059 | 1.499 | 6.10 | 6.3 |
16 | 19/29 | 0.055 | 1.400 | 0.052 | 1.320 | 0.065 | 1.651 | 0.065 | 1.651 | 4.76 | 8.0 |
14 | 19/27 | 0.069 | 1.750 | 0.065 | 1.650 | 0.078 | 1.981 | 0.078 | 1.981 | 3.00 | 12.5 |
12 | 37/28 | 0.089 | 2.260 | 0.084 | 2.130 | 0.097 | 2.464 | 0.097 | 2.464 | 1.98 | 19.1 |
10 | 37/26 | 0.112 | 2.840 | 0.106 | 2.690 | 0.120 | 3.048 | 0.120 | 3.048 | 1.24 | 29.4 |