Marine Cable  

Marine Cable

P15 UX 0.6/1kV

Applications :

  • These cables are flame retardant, low smoke and halogen free, used for earthing and bonding services.

Standards :

  • IEC 60092-353 IEC 60092-359
    IEC 60332-1 IEC 60332-3-22
    IEC 60754-1,2 IEC 61034-1,2
    NEK 606:2004  
 

 

Construction :

  • Conductors : Tinned annealed stranded copper to IEC 60228 class 2 or class 5.
  • Insulation : Halogen free thermosetting compound, SHF2. When used as protective earth (PE) wire, the cables coloured yellow/green. When used as single wire, the cables coloured off-white, black, red or blue.

Electrical Characteristics :

  • Nominal Cross Section Area mm² 10 16 25 35 50 70
    Nominal Conductor Diameter mm 4 5.1 6.5 7.4 8.7 10.3
    Maximum DC Resistant@20℃ Ω/km 1.84 1.16 0.734 0.529 0.391 0.27
    Continuous Current Rating@45℃1 Core A 72 96 127 157 196 242
    Short Circuit Current 1s A 1430 2290 3580 5010 7150 10020
    Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1
  • Nominal Cross Section Area mm² 95 120 150 185 240 300
    Nominal Conductor Diameter mm 12.2 13.8 15.1 17.0 19.6 21.9
    Maximum DC Resistant@20℃ Ω/km 0.195 0.154 0.126 0.1 0.0762 0.0607
    Continuous Current Rating@45℃1 Core A 293 339 389 444 522 601
    Short Circuit Current 1s A 13590 17170 21460 26470 34340 42930
    Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Mechanical and Thermal Properties :

  • Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
  • Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of cores×Cross section (mm²) Nominal Insulation Thickness mm Nominal Overall Diameter mm Nominal Weight kg/km
1×10 2.0 8.2 160
1×16 2.1 9.4 230
1×25 2.4 11.3 350
1×35 2.4 12.4 450
1×50 2.7 14.4 600
1×70 3.0 16.7 840
1×95 3.0 18.6 1110
1×120 3.1 20.3 1360
1×150 3.4 22.4 1660
1×185 3.7 24.9 2080
1×240 4.0 28.1 2690
1×300 4.3 31.0 3330