Thermocouple Cables 

Thermocouple Cables

Part 2 Type 1 PVC Insulated Unscreened PVC Sheathed Thermocouple Cables

Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.

Types: KX, JX & TX

Conductors: 0.5sqmm & 0.75sqmm class 5 Flexible copper, 1.5sqmm class 2 stranded copper

Insulation: PVC (Polyvinyl chloride)

Sheath/Jacket: PVC (Polyvinyl chloride)

Colour: Black, blue, brown, green & red 

Voltage: 300/500V

Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems

BS5308 Part 2, Insulated cables, instrumentation, PVC

Part 2 Type 1 PVC Insulated Unscreened PVC Sheathed Thermocouple Cables

Size sq
(mm)

Stranding
(mm)

RT of Insulation
(mm)

Diameter over Laid Up Cores
(mm)

RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

0.22

7/0.2

0.5

1.6 x 3.2

0.8

3.2 x 4.8

23

0.5

16/0.2

0.6

2.1 x 4.3

0.8

3.7 x 5.9

35

0.75

24/0.2

0.6

2.3 x 4.7

0.8

3.9 x 6.3

42

1.0
32/0.2
0.6
2.5 x 5.0
0.8
4.1 x 6.7
50

1.3

1/1.29

0.6

2.5 x 5.0

0.8

4.1 x 6.6

55

IEC 60584 Tolerences for Extension & Compensating Cables

Type

Tolerence
1

Tolerence
2

Cable Temperature Range

Measuring Junction Temperature

KX

+/-60μV (+/-1.5°C)

+/-100μV (+/-2.5°C)

-25°C - +200°C

900°C

TX
+/-30μV (+/-0.5°C)
+/-60μV (+/-1.0°C)
-25°C - +100°C
300°C

JX

+/-85μV (+/-1.5°C)

+/-140μV (+/-2.5°C)

-25°C - +200°C

500°C