Thermocouple Cables 

Thermocouple Cables

Part 1 Type 1 PE Insulated Collective Screen PVC Sheathed Thermocouple Cables

Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.

Types: KCB & KX

Conductors: 1.3sqmm: Class 1 solid copper, 0.5sqmm Class 5 flexible copper

Insulation: PE (Polyethylene)

Screen: CAM (Collective aluminium mylar)

Sheath/Jacket: PVC (Polyvinyl chloride)

Colour: Green & Yellow

Voltage: 300/500 V

Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems

BS5308 Part 1, Insulated cables, instrumentation, PE

Part 1 Type 1 PE Insulated Collective Screen PVC Thermocouple Cables

Size sq
(mm)

Stranding
(mm)

RT of Insulation
(mm)

Diameter over Screen
(mm)

RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

0.5

1/0.8

0.5

3.9

0.8

5.5

35

0.5

16/0.2

0.6

4.8

0.8

6.4

42

0.75

24/0.2

0.6

5.2

0.8

6.8

49

1.3

1/1.29

0.6

5.3

0.8

6.9

59

IEC 60584 Tolerences for Extension & Compensating Cables

Type

Tolerence
1

Tolerence
2

Cable Temperature Range

Measuring Junction Temperature

KX

+/-60μV (+/-1.5°C)

+/-100μV (+/-2.5°C)

-25°C - +200°C

900°C

VX - KCB

-

+/-140μV (+/-2.5°C)

0°C - +100°C

900°C