Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL,GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
Industrial Cables
Mining Cables
Undersea Cables
Military Cables
Marine Cables
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05V2V2-F/H05V2V2H2-F

Application and Description

These cables are suitable for domestic premises, kitchen, office for light service or light portable
apparatuses. With their special insulation and sheath compounds these cables are adapt for apparatus in
kitchen and heating and for use in zones with high temperature (like lighting system apparatuses) without
contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings
or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high
temperature use, skin contact must be avoided

Standard and Approval

<HAR>HD 21.12; HD 308 S2, DIN VDE 0281 part 1, part 12, DIN VDE 0293 part 308, DIN VDE 0295
CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), CENELEC HD 21.12 S1 /EN50265-2-1

Cable Construction

- Bare copper fine wire conductor
- Stranded to DIN VDE 0295 cl. 5, IEC 60228 cl. 5 and HD 383
- PVC core insulation T13 to VDE-0281 Part 1
- Green-yellow grounding (3 conductors and above)
- Color coded to VDE-0293-308
- PVC outer jacket TM3

          

Technical Characteristics

- Working voltage: 300/500 volts
- Test voltage: 2000 volts
- Flexing bending radius: 15 x Ø
- Static bending radius: 4 x Ø
- Flexing temperature: +5º C to +90º C
- Static temperature: -40º C to +90º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H05V2V2-F
18(24/32)
2 x 0.75
0.6
0.8
6.2
14.4
54.2
18(24/32)
3 x 0.75
0.6
0.8
6.6
21.6
65
18(24/32)
4 x 0.75
0.6
0.8
7.1
29
77.7
18(24/32)
5 x 0.75
0.6
0.9
8
36
97.3
17(32/32)
2 x 1.00
0.6
0.8
6.4
19
60.5
17(32/32)
3 x 1.00
0.6
0.8
6.8
29
73.1
17(32/32)
4 x 1.00
0.6
0.9
7.6
38
93
17(32/32)
5 x 1.00
0.6
0.9
8.3
48
111.7
16(30/30)
2 x 1.50
0.7
0.8
7.4
29
82.3
16(30/30)
3 x 1.50
0.7
0.9
8.1
43
104.4
16(30/30)
4 x 1.50
0.7
1.0
9
58
131.7
16(30/30)
5 x 1.50
0.7
1.1
10
72
163.1
14(30/50)
2 x 2.50
0.8
1.0
9.2
48
129.1
14(30/50)
3 x 2.50
0.8
1.1
10
72
163
14(30/50)
4 x 2.50
0.8
1.1
10.9
96
199.6
14(30/50)
5 x 2.50
0.8
1.2
12.4
120
245.4
12(56/28)
3 x 4.00
0.8
1.2
11.3
115
224
12(56/28)
4 x 4.00
0.8
1.2
12.5
154
295
12(56/28)
5 x 4.00
0.8
1.4
13.7
192
361
10(84/28)
3 x 6.00
0.8
1.1
13.1
181
328
10(84/28)
4 x 6.00
0.8
1.3
13.9
230
490
H05V2V2H2-F
18(24/32)
2 x 0.75
0.6
0.8
4.2 x 6.8
14.1
48
17(32/32)
2 x 1.00
0.6
0.8
4.4 x 7.2
19
57