Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL,GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
Industrial Cables
Mining Cables
Undersea Cables
Military Cables
Marine Cables
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05BN4-F

Application and Description

These EPR (ethylen-propylen rubber) insulated and CSP (chlorosulphonated polyethylene rubber or similar)
sheathed electric cables can be used either in dry, humid or wet places or in contact with oil or grease, in
weather conditions and under weak mechanical stress, for example for power supply to small appliances
in industrial plants, machine shops, heating plates, portable lamps, farming equipment etc. They are also
suitable for caravans and camping equipment... The maximum conductor temperature in normal use: 90°C.
While high temperature use, skin contact must be avoided.

Standard and Approval

<HAR> CENELEC HD 22.12 S1, CEI 20-19/12, CEI 20-35 (EN 60332-1), BS6500, BS7919,
ROHS compliant, VDE 0282 Part-12, IEC 60245-4, CE Low-Voltage

Cable Construction

- Fine bare copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- EPR(Ethylene Propylene Rubber) rubber EI7 insulation
- Color code VDE-0293-308
- CSP(Chlorosulphonated Polyethylene) outer jacket EM7

Technical Characteristics

- Working voltage: 300/500 volts
- Test voltage: 2000 volts
- Flexing bending radius: 6.0 x Ø
- Fixed bending radius: 4.0 x Ø
- Temperature Range: -20º C to +90º C
- Maximum Short Circuit Temperature: +250º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
2 x 0.75
0.8
6.1
29
54
18(24/32)
3 x 0.75
0.6
0.9
6.7
43
68
18(24/32)
4 x 0.75
0.6
0.9
7.3
58
82
18(24/32)
5 x 0.75
0.6
1.0
8.1
72
108
2 x 1
0.6
0.9
6.6
19
65
17(32/32)
3 x 1
0.6
0.9
7.0
29
78
17(32/32)
4 x 1
0.6
0.9
7.6
38
95
17(32/32)
5 x 1
0.6
1.0
8.5
125