Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL,GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
Industrial Cables
Mining Cables
Undersea Cables
Military Cables
Marine Cables
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Rubber

Insulated Cables

Industrial

Twinax Cables

Industrial 

Data Cables

Industrial 

Coaxial Cables

Industrial Optical

Fiber Cables

 

Industrial Cables

XLPE/Nylon/HYP Thermoset Super Flexing Control Cable 

Applications:

Any continuous flexing application requiring a small diameter flexible cable 

ROBOTS 

Machine tools 

Car body and vehicle assembly 

Material handling equipment 

Power tracks

Features:

Rated at 90°C, 75°C wet 

Extremely flexible with long flex life 

Small diameter 

Thermoset rubber insulation and jacket 

Oil resistant 

Suitable for indoor and outdoor applications 

Meets cold bend test at -30°C 

Meets cold impact test at -25°C

Construction: 

Conductor: 

18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3 

Class M: 18 AWG thru 16 AWG 

Class K: 14 AWG thru 10 AWG 

Stranding per ASTM B8

Insulation: 

Thermoset Cross-Linked Polyethylene (XLPE) with clear Polyamide (nylon) 

Color-Coded: 

All conductors red, except #2 is white and #3 is green, all with alpha-numeric designations

Jacket: 

Lead-Free Hypalon Chlorosulfonated Polyethylene (CSPE)/Elastomer blend

Approvals: 

Industry Compliances: 

UL Type TC / CSA CIC

Flame Tests Compliances: 

IEEE 1202 (70,000 BTU/hr) CSA FT4 

IEEE 383 (70,000 BTU/hr)

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

No. of Cond.

Conductor Stranding

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. (in)

Min. Bend Radius

Approx LBS/MFT

18

6

41/34

0.02

0.045

0.39

3

93

18

8

41/34

0.02

0.045

0.455

3.5

116

18

12

41/34

0.02

0.045

0.49

4

155

18

16

41/34

0.02

0.06

0.57

4.5

211

18

22

41/34

0.02

0.06

0.65

5

272

18

31

41/34

0.02

0.06

0.75

6

366

18

41

41/34

0.02

0.08

0.88

7

498

18

60

41/34

0.02

0.08

1

8

676

16

6

65/34

0.02

0.045

0.43

3.5

122

16

8

65/34

0.02

0.045

0.49

4

152

16

12

65/34

0.02

0.06

0.575

4.5

216

16

16

65/34

0.02

0.06

0.63

5

277

16

22

65/34

0.02

0.06

0.725

5.5

368

16

31

65/34

0.02

0.06

0.835

6.5

491

16

41

65/34

0.02

0.08

0.985

8

683

16

60

65/34

0.02

0.08

1.115

9

912

14

6

41/30

0.02

0.045

0.46

3.5

159

14

8

41/30

0.02

0.06

0.56

4.5

219

14

12

41/30

0.02

0.06

0.62

5

295

14

16

41/30

0.02

0.06

0.68

5.5

375

14

22

41/30

0.02

0.06

0.785

6

495

12

6

65/30

0.02

0.06

0.555

4.5

238

12

8

65/30

0.02

0.06

0.635

5

300

12

12

65/30

0.02

0.06

0.705

5.5

433

12

16

65/30

0.02

0.06

0.78

6

535

12

22

65/30

0.02

0.08

0.945

7.5

789

10

6

105/30

0.026

0.06

0.655

5

350

10

8

105/30

0.026

0.06

0.755

6

450

10

12

105/30

0.026

0.08

0.885

7

675

10

16

105/30

0.026

0.08

1.145

9

905