Câbles Coaxiaux  

URM Coax

URM 70 RBS

Product Name/Code: URM70 RBS

 

Performance électrique

Application:

Max.Conductor DC Resistance at 20 ℃(Ω /Km )9 3.800

93.8

For communication and signal control systems.

Min.Insulation DC Resistance at 20 ℃( M Ω *Km )

>500

Référence à la norme

Température de fonctionnement( ℃ )

70

Customer's sample spec.and the general standard

Voltage Rating(V)

30

Cable Construction

Capacité(pF/m)

67+/-5

Number of Cores

1

Velocity ratio(%)

66.7

Conductor

Bare Copper

Impédance( Ω )

75+/-3

Construction

0.19/7

Attenuation at 20 ℃ (-dB/100m)

Conductor Dia.(mm)

0.58

100MHz

13.8

Isolation

Solid PE

300MHz

25.5

Min. Epaisseur (mm)

1.310

500MHz

33.0

Isolation Diamètre(±0.03mm)

3.20

700MHz

41.5

Screening(mm)

Bare Copper Braid

900MHz

47.8

Construction

16 / 6/0.12

1000MHz

50.1

Braid Coverage(%)

81

Inner Sheathing

LDPE

Epaisseur (mm)

1.42

Diameter(mm)

5.80

Jacket Color

Nature

Outer Sheathing

HDPE

Epaisseur (mm)

0.8

Cable Diameter(mm)

7.40

Panneau de revêtement composé

PVC/LSF/LSOH

Identification de base / Code de Couleur

According to customer request

Rayon de courbure

6xOverall Diameter

Evaluation de température

70C

Tension nominale

300/500V

Feu

Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH )