| Câbles Coaxiaux | ||||||||||||||
CT Coax
CCL-VATC-03 |
|||||
Product Name/Code : CCL-VATC-03 |
Performance électrique |
||||
Application : |
Electrical Characteristics: |
||||
For communication and signal control systems. |
Fréquence |
Atténuation |
|||
Référence à la norme |
(MHz) |
(dB/100m) |
|||
Customer's sample spec. and the general standard |
53 |
4.8 |
|||
100 |
6.00 |
||||
Cable Construction |
250 |
9.1 |
|||
Centre Chef d'orchestre |
Bare Copper |
300 |
10.8 |
||
Dia.(mm) |
1/1.0 |
450 |
12.30 |
||
Isolation |
Solid PE |
800 |
17.0 |
||
Nom.Epaisseur(mm) |
1.9 |
880 |
19.10 |
||
Isolation Dia. (±0.03mm) |
4.8 |
1000 |
19.90 |
||
Bonded Al/Polyester Foil |
1400 |
24.00 |
|||
Coverage Area(%) |
>=100 |
1770 |
27.0 |
||
Tinned Copper Braid Shield |
2000 |
27.9 |
|||
Construction |
16/ 6/0.12 |
2150 |
30.1 |
||
Coverage Area(%) |
>=60 |
2500 |
33.1 |
||
Jacket |
PVC |
||||
Nom. Thickness(mm) |
0.9 |
Température de fonctionnement( ℃ ) |
60 |
||
Cable Dia.(±0.10mm) |
6.8 |
Capacité(pF/m) |
52 |
||
Composé Jacket |
PVC/LSF/LSOH |
Impédance(+/-3 Ω ) |
75 |
||
Identification de base / Code de Couleur |
According to customer request |
Velocity ratio (+/-5%) |
83 |
||
Rayon de courbure |
6 x Overall Diameter |
||||
Evaluation de température |
70 ℃ |
||||
Tension nominale |
300/500V |
||||
Feu |
|||||
|
|||||