    Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Jacket, 8kV

    • Mine Power Feeder Cable, CPE Jacket, 8kV
    • Mine Power Feeder Cable, CPE Jacket, 8kV

    Application

    These cables are designed for connections between units of mine distribution systems, suitable for installed in duct, conduit or open air and for direct burial in wet and dry locations.

    Standards

    • ICEA S-75-381/NEMA WC 58
    • ASTM B-8
    • CAN/CSA C22.2 No. 96

    Construction

    Conductors Stranded annealed bare copper conductor.
    Conductor Shield Conducting layer.
    Insulation Ethylene Propylene Rubber (EPR).
    Insulation Shield Conducting layer + copper tape.
    Ground Check Conductor Copper conductor with a yellow polypropylene insulation.
    Grounding Conductor Tinned copper conductor
    Jacket Chlorinated Polyethylene (CPE), black.

    Options

    Other jacket materials such as CSP/PCP/NBR/PVC/TPU are available upon request.

    Mechanical and Thermal Properties

    Minimum Bending Radius 12×OD
    Maximum Conductor Operating Temperature +90℃

    Dimensions and Weight

    Construction No. of Strands Grounding Conductor Size Ground Check Conductor Size Nominal Insulation Thickness Nominal Jacket Thickness Nominal Overall Diameter Height×Width Nominal Weight Ampacity
    No. of cores × AWG/kcmil - AWG/kcmil AWG/kcmil inch mm inch mm inch mm lbs/kft kg/km A
    3×6 7 10 8 0.115 2.9 0.11 2.8 1.41 35.8 1175 1749 93
    3×4 7 8 8 0.115 2.9 0.11 2.8 1.52 38.6 1608 2392 122
    3×2 7 6 8 0.115 2.9 0.11 2.8 1.58 40.1 1919 2855 159
    3×1 19 5 8 0.115 2.9 0.11 2.8 1.66 42.2 2507 3730 184
    3×1/0 19 4 8 0.115 2.9 0.11 2.8 1.74 44.2 2660 3958 211
    3×2/0 19 3 8 0.115 2.9 0.14 3.6 1.90 48.3 3257 4846 243
    3×3/0 19 2 8 0.115 2.9 0.14 3.6 2.00 50.8 3432 5107 279
    3×4/0 19 1 8 0.115 2.9 0.14 3.6 2.12 53.8 4382 6520 321
    3×250 37 1/0 8 0.115 2.9 0.14 3.6 2.22 56.4 4965 7387 355
    3×350 37 2/0 8 0.115 2.9 0.14 3.6 2.43 61.7 6484 9647 435
    3×500 37 4/0 8 0.115 2.9 0.14 3.6 2.70 68.6 8857 13178 536

    Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.

     