?????????????? Adobe Flash Player?

?? Adobe Flash Player

Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables

Airport Cables

Belden Equivalent Cables

Bus Cables

Cable Glands

Cables for Oil Industry

Coaxial Cables

Control Cables

Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)

Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Power Cables
Photovoltaic Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Shipboard Cables(JIS)
Special Cables
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Special Cables

CALETRUCK M,N

Temperature range:

  • CALETRUCK M: -40°C to +85°C
  • CALETRUCK N: -40°C to +85°C

Test voltage:

  • CALETRUCK M: 2000 V
  • CALETRUCK N: 3000 V

Minimum bending radius:

  • CALETRUCK M: fixed installation 5x cable Ø
  • CALETRUCK N: fixed installation 15x cable Ø

Insulation resistance:

  • CALETRUCK M: min. 20 MOhm x km
  • CALETRUCK N: min. 20 MOhm x km

Nominal voltage:

  • CALETRUCK N: 75 V DC

Properties

  • CALETRUCK M:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Polarity easy to determine by a white line on the jacket above the white conductor
  • CALETRUCK N:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Complies with GGVS regulations
  • Approved and tested by the TÜV technical inspectorate
  • The additional jacket means that the cable is very robust, and can be installed without a corrugated conduit
  • Installation time is shorter due to twin design
  • Polarity is easy to determine even without stripping thanks to an imprint with the type designation and on the jacket over the positive conductor. This helps prevent wrong connections
  • The special construction of the conductor enables optimal crimping
  • Easy mechanical separation of the jacket web

CALETRUCK M

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x1.5 6.8 28.8 90.0 16
2x1.5 6.8 28.8 90.0 16
272 2x1.5 6.8 28.8 90.0 16

CALETRUCK N

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x2.5 9.4 48.0 87.0 14
2x4 11.5 77.0 125.0 12
2x6 15.2 116.0 175.0 10
2x10 18.8 192.0 270.0 8
2x16 21.0 308.0 390.0 6
2x25 25.6 480.0 575.0 4
2x35 28.0 672.0 820.0 2
2x50 33.0 960.0 1065.0 1
2x70 36.0 1344.0 1475.0 2/0