    AJ-2Y2YDB2Y S(H115)/S(H145)/S(H95)

    • AJ-2Y2YDB2Y S(H115)/S(H145)/S(H95)
    • AJ-2Y2YDB2Y S(H115)/S(H145)/S(H95)

    Application

    The cables are designed for transmission of service tensions up to 600 VDC / 420 Veff AC100Hz in railway signalling networks, and are suitable for installation in ducts or laying directly into the ground.

    Standard

    • Dlk 1.013.107y
    • Dlk 1.013.108y (for 1.4/1.8mm conductor H95 type)
    • Dlk 1.013.110y

    Cable Construction

    • Type CodesConductors: Solid annealed copper, 0.9, 1.4 or 1.8 mm nominal diameter.
    • Insulation: Solid polyethylene.
    • Stranding: Single conductors are helically stranded in concentric layers. Cables from 14 conductors on have two extra conductors of 0.5mm with perforated insulation (surveillance conductors).
    • Core Wrapping: Plastic tape(s) with overlapping.
    • Inner Sheath: Low density polyethylene.
    • Electrostatic Shield: One layer of helically applied copper wires (0.9, 1.2, 1.4 or 1.8mm).
    • Electromagnetic Shield: Two helically applied steel tapes (0.5 or 0.8mm thick, depending on required reduction factor).
    • Outer Sheath: Low density polyethylene.
    • AJ- outdoor cable with protection against inductive infl uences
    • 2Y solid PE conductor insulation
    • 2Y inner PE sheath
    • D copper wire concentric screen
    • B steel tape armor
    • 2Y outer PE sheath
    • S signal cable
    • LG layer stranding
    • H (n) operating capacity

    Electrical Characteristics at 20℃

    Nominal Conductor Diameter mm 0.9 1.4 1.8
    Maximum Conductor Resistance Ω/km 28.9 11.9 7.2
    Minimum Insulation Resistance @500 V DC (1min) MΩ.km 10000 10000 10000
    Maximum Mutual Capacitance @800Hz (AC) nF/km 15 145/95* 145/95*
    Dielectric Strength, conductor to conductor (DC voltage 1min) V 3535 3535 3535
    Surveillance Conductors        
    Loop resistance, maximum Ω/km 190 190 190
    Insulation resistance        
    - dry cable core, minimum MΩ.km 1000 1000 1000
    - wet cable core, maximum KΩ.km 30 30 30
    Nominal Reduction Factor @ 100 V/km, 16 2/3 Hz        
    rk 401 series   0.15 0.15 0.15
    rk 501 series   0.35 0.35 0.35
    rk 601 series   0.55 0.55 0.55
    Operating Voltage AC/DC V 420/600 420/600 420/600
    Test Voltage@50 Hz 1 min        
    Core to Core Veff 2500 2500 2500
    Core to Screen Veff 2500 2500 2500

    *The value“ 95” is only for cables with 1.4/1.8mm conductors according to Dlk 1.013.108y.

    Mechanical and Thermal Properties

    • Minimum Bending Radius: 10×OD
    • Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)

    Dimensions and Weight

    AJ-2Y2YDB2Y n×1×0.9 S(H115)

    Cable Code Number of
    conductors
    (n)
    Nominal Sheath Thickness
    mm
    Nominal Overall
    Diameter
    mm
    Nominal
    Weight
    Inner Outer kg/km
    Inner Outer
    0.9mm Conductor, 1.55mm Insulated Wire rk 601 Series
    RS107y-2Y2YDB2Y-10C0.9-S(H115)-R6 10 1.3 1.2 19.0 520
    RS107y-2Y2YDB2Y-20C0.9-S(H115)-R6 20 1.3 1.2 20.0 650
    RS107y-2Y2YDB2Y-30C0.9-S(H115)-R6 30 1.3 1.2 22.0 780
    RS107y-2Y2YDB2Y-50C0.9-S(H115)-R6 50 1.3 1.2 25.0 1010
    RS107y-2Y2YDB2Y-80C0.9-S(H115)-R6 80 1.3 1.2 29.0 1330
    RS107y-2Y2YDB2Y-120C0.9-S(H115)-R6 120 1.3 1.3 32.0 1740
    RS107y-2Y2YDB2Y-160C0.9-S(H115)-R6 160 1.3 1.3 35.0 2310
    RS107y-2Y2YDB2Y-200C0.9-S(H115)-R6 200 1.3 1.3 38.0 2520
    0.9mm Conductor, 1.55mm Insulated Wire rk 501 Series
    RS107y-2Y2YDB2Y-10C0.9-S(H115)-R5 10 1.3 1.2 19.0 600
    RS107y-2Y2YDB2Y-20C0.9-S(H115)-R5 20 1.3 1.2 20.0 740
    RS107y-2Y2YDB2Y-30C0.9-S(H115)-R5 30 1.3 1.2 22.0 890
    RS107y-2Y2YDB2Y-50C0.9-S(H115)-R5 50 1.3 1.3 25.0 1150
    RS107y-2Y2YDB2Y-80C0.9-S(H115)-R5 80 1.3 1.3 29.0 1480
    RS107y-2Y2YDB2Y-120C0.9-S(H115)-R5 120 1.5 1.3 32.0 1910
    RS107y-2Y2YDB2Y-160C0.9-S(H115)-R5 160 1.5 1.3 35.0 2530
    RS107y-2Y2YDB2Y-200C0.9-S(H115)-R5 200 1.5 1.5 38.0 2730

    AJ-2Y2YDB2Y n×1×1.4/1.8 S(H145)

    Cable Code Number of
    conductors
    (n)
    Nominal Sheath Thickness
    mm
    Nominal Overall
    Diameter
    mm
    Nominal
    Weight
    Inner Outer kg/km
    Inner Outer
    1.4mm Conductor, 2.2mm Insulated Wire rk 601 Series
    RS107y-2Y2YDB2Y-10C1.4-S(H145)-R6 10 1.3 1.2 21 670
    RS107y-2Y2YDB2Y-20C1.4-S(H145)-R6 20 1.3 1.2 23.5 940
    RS107y-2Y2YDB2Y-30C1.4-S(H145)-R6 30 1.3 1.2 27 1180
    RS107y-2Y2YDB2Y-50C1.4-S(H145)-R6 50 1.3 1.2 31 1650
    RS107y-2Y2YDB2Y-80C1.4-S(H145)-R6 80 1.3 1.2 35 2270
    RS107y-2Y2YDB2Y-120C1.4-S(H145)-R6 120 1.3 1.3 41 3110
    RS107y-2Y2YDB2Y-160C1.4-S(H145)-R6 160 1.3 1.3 46 3900
    RS107y-2Y2YDB2Y-200C1.4-S(H145)-R6 200 1.3 1.3 49 4670
    1.4mm Conductor, 2.2mm Insulated Wire rk 501 Series
    RS107y-2Y2YDB2Y-10C1.4-S(H145)-R5 10 1.3 1.2 21 780
    RS107y-2Y2YDB2Y-20C1.4-S(H145)-R5 20 1.3 1.2 23.5 1070
    RS107y-2Y2YDB2Y-30C1.4-S(H145)-R5 30 1.3 1.2 26 1320
    RS107y-2Y2YDB2Y-50C1.4-S(H145)-R5 50 1.3 1.3 31 1810
    RS107y-2Y2YDB2Y-80C1.4-S(H145)-R5 80 1.3 1.3 35 2460
    RS107y-2Y2YDB2Y-120C1.4-S(H145)-R5 120 1.5 1.3 42 3380
    RS107y-2Y2YDB2Y-160C1.4-S(H145)-R5 160 1.5 1.3 46 4190
    RS107y-2Y2YDB2Y-200C1.4-S(H145)-R5 200 1.5 1.5 49 5000
    1.4mm Conductor, 2.2mm Insulated Wire rk 401 Series
    RS107y-2Y2YDB2Y-10C1.4-S(H145)-R4 10 1.3 1.2 23 960
    RS107y-2Y2YDB2Y-20C1.4-S(H145)-R4 20 1.3 1.2 25.6 1260
    RS107y-2Y2YDB2Y-30C1.4-S(H145)-R4 30 1.3 1.3 28 1940
    RS107y-2Y2YDB2Y-50C1.4-S(H145)-R4 50 1.3 1.3 33 2450
    RS107y-2Y2YDB2Y-80C1.4-S(H145)-R4 80 1.5 1.3 38 3280
    RS107y-2Y2YDB2Y-120C1.4-S(H145)-R4 120 1.5 1.5 44 4290
    RS107y-2Y2YDB2Y-160C1.4-S(H145)-R4 160 1.5 1.5 48 5200
    RS107y-2Y2YDB2Y-200C1.4-S(H145)-R4 200 1.5 1.5 52 6060
    1.8mm Conductor, 2.7mm Insulated Wire rk 601 Series
    RS107y-2Y2YDB2Y-10C1.8-S(H145)-R6 10 1.3 1.2 23 850
    RS107y-2Y2YDB2Y-20C1.8-S(H145)-R6 20 1.3 1.2 27 1260
    RS107y-2Y2YDB2Y-30C1.8-S(H145)-R6 30 1.3 1.3 30 1620
    RS107y-2Y2YDB2Y-50C1.8-S(H145)-R6 50 1.3 1.3 36 2080
    RS107y-2Y2YDB2Y-80C1.8-S(H145)-R6 80 1.5 1.3 41 3310
    RS107y-2Y2YDB2Y-120C1.8-S(H145)-R6 120 1.5 1.5 48 4570
    RS107y-2Y2YDB2Y-160C1.8-S(H145)-R6 160 1.5 1.5 54 5950
    RS107y-2Y2YDB2Y-200C1.8-S(H145)-R6 200 1.5 1.5 58 6970
    1.8mm Conductor, 2.7mm Insulated Wire rk 501 Series
    RS107y-2Y2YDB2Y-10C1.8-S(H145)-R5 10 1.3 1.2 23 970
    RS107y-2Y2YDB2Y-20C1.8-S(H145)-R5 20 1.3 1.2 27 1410
    RS107y-2Y2YDB2Y-30C1.8-S(H145)-R5 30 1.3 1.3 30 1780
    RS107y-2Y2YDB2Y-50C1.8-S(H145)-R5 50 1.3 1.3 36 2520
    RS107y-2Y2YDB2Y-80C1.8-S(H145)-R5 80 1.5 1.3 42 3570
    RS107y-2Y2YDB2Y-120C1.8-S(H145)-R5 120 1.5 1.5 49 5950
    RS107y-2Y2YDB2Y-160C1.8-S(H145)-R5 160 1.5 1.5 55 6170
    RS107y-2Y2YDB2Y-200C1.8-S(H145)-R5 200 1.5 1.5 59 7380
    1.8mm Conductor, 2.7mm Insulated Wire rk 401 Series
    RS107y-2Y2YDB2Y-10C1.8-S(H145)-R4 10 1.3 1.2 25 1160
    RS107y-2Y2YDB2Y-20C1.8-S(H145)-R4 20 1.3 1.2 29 1700
    RS107y-2Y2YDB2Y-30C1.8-S(H145)-R4 30 1.3 1.3 32 2400
    RS107y-2Y2YDB2Y-50C1.8-S(H145)-R4 50 1.3 1.3 38 3350
    RS107y-2Y2YDB2Y-80C1.8-S(H145)-R4 80 1.5 1.3 44 3310
    RS107y-2Y2YDB2Y-120C1.8-S(H145)-R4 120 1.5 1.5 51 4900
    RS107y-2Y2YDB2Y-160C1.8-S(H145)-R4 160 1.5 1.5 57 7340
    RS107y-2Y2YDB2Y-200C1.8-S(H145)-R4 200 1.5 1.5 61 8650

    AJ-2Y2YDB2Y n×1×1.4/1.8 S(H95)

    Cable Code Number of
    conductors
    (n)
    Nominal Sheath
    Thickness
    mm
    Nominal Overall
    Diameter
    mm
    Nominal Weight
    kg/km
    Inner Outer
    1.4mm Conductor, 2.7mm Insulated Wire rk 501 Series
    RS108y-2Y2YDB2Y-10C1.4-S(H95)-R5 10 1.3 1.2 22.0 900
    RS108y-2Y2YDB2Y-14C1.4-S(H95)-R5 14 1.3 1.2 24.0 1010
    RS108y-2Y2YDB2Y-20C1.4-S(H95)-R5 20 1.3 1.2 27.0 1220
    RS108y-2Y2YDB2Y-30C1.4-S(H95)-R5 30 1.3 1.2 30.0 1520
    RS108y-2Y2YDB2Y-50C1.4-S(H95)-R5 50 1.3 1.3 35.0 2090
    1.4mm Conductor, 2.7mm Insulated Wire rk 401 Series
    RS108y-2Y2YDB2Y-30C1.4-S(H95)-R4 30 1.3 1.2 32.0 2150
    RS108y-2Y2YDB2Y-50C1.4-S(H95)-R4 50 1.3 1.3 38.0 2900
    1.8mm Conductor, 3.4mm Insulated Wire rk 501 Series
    RS108y-2Y2YDB2Y-10C1.8-S(H95)-R5 10 1.3 1.2 25.0 1130
    RS108y-2Y2YDB2Y-14C1.8-S(H95)-R5 14 1.3 1.2 27.0 1330
    RS108y-2Y2YDB2Y-20C1.8-S(H95)-R5 20 1.3 1.2 30.0 1620
    RS108y-2Y2YDB2Y-30C1.8-S(H95)-R5 30 1.3 1.3 34.0 2340
    RS108y-2Y2YDB2Y-50C1.8-S(H95)-R5 50 1.3 1.3 42.0 3020
    1.8mm Conductor, 3.4mm Insulated Wire rk 401 Series
    RS108y-2Y2YDB2Y-30C1.8-S(H95)-R4 30 1.3 1.3 37.0 2880
    RS108y-2Y2YDB2Y-50C1.8-S(H95)-R4 50 1.3 1.3 44.0 3950

     

    Contact Us