Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Thermocouple Cables 

Thermocouple Cables

Part 1 Type 2 PE Insulated / Collective Screen SWA PVC Sheathed Thermocouple Cables

Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.

Types: KCB & TX

Conductors: 0.5sqmm class 5 Flexible copper, 1.8sqmm class 1 solid copper

Insulation: PE (Polyethylene)

Screen: CAM (Collective aluminium mylar)

Bedding: PE (Polyethylene)

Armour/Protection: SWA (Single wire armour)

Sheath/Jacket: PVC (Polyvinyl-Chloride)

Colour: Black or green

Voltage: 300/500V

Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems

BS5308 Part 1, Insulated cables, instrumentation, PE

Part 1 Type 2 PE Insulated / Collective Screen SWA PVC Sheathed Thermocouple Cables

Size sq
(mm)

Stranding
(mm)

RT of Insulation
(mm)
Diameter over Bedding
(mm)
Diameter of Armour Wire

Diameter over Armour
(mm)

RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

0.5

1/0.8

0.5
5.5
0.9

7.3

1.0

9.3

142

1.3

1/1.29

0.6
6.9
0.9

8.7

1.0

10.7

185

0.5 sqmm (16/0.2mm)

No. of Pairs

Nominal Diameter Laid Up Pairs
(mm)

Nominal Diameter Collective Screen
(mm)
RT of Bedding
(mm)
Diameter over Bedding
(mm)

Diameter of Armour Wire
(mm)

Diameter over Armour
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

2

4.3

4.7
0.8
6.8

0.9

8.6

11.2

260

5
9.9
10.9
1.1
13.1
0.9
14.9
17.9
470
10
13.8
14.8
1.2
17.2
1.25
19.7
22.9
810
15
16.2
17.2
1.3
19.8
1.6
23.0
26.4
1160
20
18.7
19.7
1.3
22.3
1.6
25.5
29.1
1370
30
22.9
23.9
1.5
26.9
1.6
30.1
33.9
1760

50

29.5

30.5
1.7
33.9

2.0

37.9

42.1

2730

0.7 sqmm (24/0.2mm)

No. of Pairs

Nominal Diameter Laid Up Pairs
(mm)

Nominal Diameter Collective Screen
(mm)
RT of Bedding
(mm)
Diameter over Bedding
(mm)

Diameter of Armour Wire
(mm)

Diameter over Armour
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

2

4.7

5.1
0.8
7.3

0.9

9.1

11.9

310

5
10.4
11.1
1.2
14.3
1.25
16.8
19.8
710
10
13.6
14.6
1.3
18.7
1.6
21.9
25.3
1200
15
17.5
18.6
1.3
21.4
1.6
24.6
28.2
1500
20
19.9
21.0
1.5
24.5
1.6
27.7
31.3
1700
30
23.2
24.5
1.7
29.5
2.0
33.5
37.5
2500

50

31.0

32.5
2.0

37.4

2.0

42.4

47.0

3300

Operating Temperature: Max 105°C, Min -10°C, Min bending 0°C

Min bending radius: 6 X Overall Diameter

Conductor Dimensions

Size & Stranding: 0.5 sqmm (16/0.2mm), 0.75 sqmm (24/0.2mm)