Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
    Cavo Fibra Ottica 
 

Mechanical & Environmental Properties for Single Mode Fiber

Testing Parameters

EIA/TIA-455 FOTP Number

IEC-794-1 Test Method

EN 187000Test Method

Maximum Increased loss

Tensile Load & Bending

33

E1

501

<0.05dB (90%); <0.15dB (100%)

Low & HighTemperature Bend

37

E11

<0.05dB (90%); <0.15dB (100%)

Compression loading (Crush)

41

E3

504

<0.05dB (90%); <0.15dB (100%) 440N/km(250lb/in) load

Impact Resistance

25

E4

505

<0.05dB (90%); <0.15dB (100%)

Twist (Torson)

85

E7

508

<0.05dB (90%); <0.15dB (100%)

Cyclic Flexing(Repeated Bending)

104

E6

509

<0.05dB (90%); <0.15dB (100%)

External freezing

98

F6

<0.05dB (90%); <0.15dB (100%)

Temperature Cycling

3

F1

601

<0.05dB (90%); <0.15dB (100%)

Fiber Stripability

178

B6

<8.9N(2lbf) on unaged and aged fi ber; >1.3N(0.3lbf) on unaged and aged fi ber

Cable Aging

82

F5

<0.1dB (90%); <0.25dB (100%)

Water Penetration

82

F5

No flow after 24 hours from 1 meter length of cable

Compound Flow (Drip)

81

E14

80 C 24 hrs duration, no drip

Mechanical & Environmental Properties for Multi Mode Fiber

Testing Parameters

EIA/TIA-455 FOTP Number

IEC-794-1 Test Method

EN 187000 Test

MethodMaximum Increased loss

Tensile Load & Bending

33

E1

501

<0.2dB

Low & HighTemperature Bend

37

E11

<0.4dB

Compression loading (Crush)

41

E3

504

<0.2dB 440N/km(250lb/in) load

Cyclic Impact

25

E4

505

<0.4dB

Twist (Torsion)

85

E7

508

<0.2dB

Cyclic Flexing(Repeated Bending)

104

E6

509

<0.2dB

External freezing

98

F6

<0.2dB

Temperature Cycling

3

F1

601

<0.05dB (90%); <0.15dB (100%)

Fiber Stripability

178

B6

<13.4N(3lbf) on unaged fi ber

Cable Aging

82

F5

<0.1dB (90%); <0.25dB (100%)

Water Penetration

82

F5

No flow after 24 hours from 1 meter length of cable

Compound Flow (Drip)

81

E14

80 C 24 hrs duration, no drip