Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Cavo di Controllo  

VDE Standard Control Cable

CY PVC/PVC /TCWB/ PVC Control Cable

Applicazione:
For use as a measuring, control and signal cable for the machine tool industry, plant construction, heating and air conditioning etc, and are particularly suitable between fixed and mobile equipment. The cable is well protected against electrical interference by the narrow weave tinned copper-wire braid screen, which ensures the undisturbed transmission of pulses and signals in electronic fields.
* Note: should not be used in any installations where the cable is subjected to repetitive flexing.
Standards: Generally BS6500 VDE0250
Direttore: Class 5 annealed copper conductors to BS6360 / VDE0295
Isolamento: PVC
Letti: PVC
Braiding: Tinned Copper Wire Braid (TCWB)
Guaina: PVC (Type TM2 to BS7655)
Tensione: 300/500V
Temperatura Voto:
Flexing -15 to +70°C
Static -35 to +70°C
Minimum bending radius: 6 x overall diameter
Core identification: Black with White numbers. (3 core and above to include Green/Yellow)
Coloured cores available on request

Current Carrying Capacity (amperes)

Nominal Cross Sectional Area

Single Phase AC or DC

Three Phase AC

mm2

Amps

Amps

0.5

3

3

0.8

6

6

1.0

10

10

1.5

16

16

2.5

25

20

4.0

32

25

6.0

51

43

10.0

70

60

16.0

94

80

The above ratings are based on cable in Free air, in an ambient air temperature of 30°C.

For ambient air temperatures other than 30°C the following rating factors should be applied:
Ratings for cables up to and including 4mm2 are based on 60°C conductor operating temperature with 6mm2 and above based on 70°C operating temperature.

Correction Factors
Cables Up To and Including 4mm2 . Assuming 60°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

Correction Factor

0.91

0.82

0.71

0.58

0.41

Cables 6mm2 and above. Assuming 70°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

60°C

Correction Factor

0.91

0.82

0.71

0.58

0.41

0.50

0.5 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C0.50SQ

2 X 0.5

5.5

46

CCL-CT-CY-3C0.50SQ

3 X 0.5

5.8

55

CCL-CT-CY-4C0.50SQ

4 X 0.5

6.4

66

CCL-CT-CY-5C0.50SQ

5 X 0.5

7.2

78

CCL-CT-CY-7C0.50SQ

7 X 0.5

8.2

95

CCL-CT-CY-12C0.50SQ

12 X 0.5

10.0

155

CCL-CT-CY-18C0.50SQ

18 X 0.5

11.7

230

CCL-CT-CY-25C0.50SQ

25 X 0.5

13.8

320

0.75 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C0.75SQ

2 X 0.75

6.3

55

CCL-CT-CY-3C0.75SQ

3 X 0.75

7.0

67

CCL-CT-CY-4C0.75SQ

4 X 0.75

7.2

80

CCL-CT-CY-5C0.75SQ

5 X 0.75

8.0

100

CCL-CT-CY-7C0.75SQ

7 X 0.75

9.0

130

CCL-CT-CY-12C0.75SQ

12 X 0.75

11.5

210

CCL-CT-CY-18C0.75SQ

18 X 0.75

13.0

260

CCL-CT-CY-25C0.75SQ

25 X 0.75

16.0

430

CCL-CT-CY-34C0.75SQ

34 X 0.75

17.5

515

CCL-CT-CY-42C0.75SQ

42 X 0.75

19.0

600

1.0 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C1.00SQ

2 X 1.0

7.0

66

CCL-CT-CY-3C1.00SQ

3 X 1.0

7.3

80

CCL-CT-CY-4C1.00SQ

4 X 1.0

8.0

100

CCL-CT-CY-5C1.00SQ

5 X 1.0

8.5

125

CCL-CT-CY-7C1.00SQ

7 X 1.0

9.2

160

CCL-CT-CY-12C1.00SQ

12 X 1.0

12.5

260

CCL-CT-CY-18C1.00SQ

18 X 1.0

14.5

375

CCL-CT-CY-34C1.00SQ

34 X 1.0

20.0

650

CCL-CT-CY-42C1.00SQ

42 X 1.0

21.5

740

1.5 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C1.50SQ

2 X 1.5

7.5

85

CCL-CT-CY-3C1.50SQ

3 X 1.5

8.3

115

CCL-CT-CY-4C1.50SQ

4 X 1.5

8.7

150

CCL-CT-CY-5C1.50SQ

5 X 1.5

9.5

168

CCL-CT-CY-7C1.50SQ

7 X 1.5

10.8

210

CCL-CT-CY-12C1.50SQ

12 X 1.5

13.5

365

CCL-CT-CY-18C1.50SQ

18 X 1.5

16.5

525

CCL-CT-CY-25C1.50SQ

25 X 1.5

19.8

765

CCL-CT-CY-34C1.50SQ

34 X 1.5

22.0

940

CCL-CT-CY-42C1.50SQ

42 X 1.5

23.8

1050

2.5 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C2.50SQ

2 X 2.5

9.5

130

CCL-CT-CY-3C2.50SQ

3 X 2.5

10.5

170

CCL-CT-CY-4C2.50SQ

4 X 2.5

11.4

210

CCL-CT-CY-5C2.50SQ

5 X 2.5

12.5

260

CCL-CT-CY-7C2.50SQ

7 X 2.5

14.0

345

4.0 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-3C4.00SQ

3 X 4.0

10.6

265

CCL-CT-CY-4C4.00SQ

4 X 4.0

11.5

350

CCL-CT-CY-5C4.00SQ

5 X 4.0

12.7

480

CCL-CT-CY-7C4.00SQ

7 X 4.0

14.0

6.0 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-4C6.00SQ

4 X 6.0

15.5

550

CCL-CT-CY-5C6.00SQ

5 X 6.0

15.7

CCL-CT-CY-7C6.00SQ

7 X 6.0

16.6

>>Return