Heim
Über uns
Produkte
Herunterladen
Technische Lib
Kontakt
Anfrage
Sitemap
Links
 

Alarm u. Audio u. Elektronisches Kabe

Belden gleichwertige Kabel

Koaxial-Kabel

SteuerKabel

LWL Kabel

Flexible Kabel

Instrumentation Kabel

Lan Kabel
EnergieKabel
Bahn-Kabel

Robotik

Rolling Stock Kabel
Gummi u. Kran Kabel
Sicherheit Kabel

Telefon Kabel

Flughafen Kabel

Bus-Kabel

Kabelverschraubungen

Daten Kabel

Heat Detection Kabel
Hochtemperatur-Kabel
Highway Kabel
Marine, Öl, Gas & Petrochemie-Kabel
Special Cables
Spiralkabel
Thermoelement-Kabel
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Rolling Stock Kabel

Rolling Stock Kabel

EN 50382 High Temperature Cable

FIREROL FRL-HT-6SURI

3.6/6 kV - High Temperature Single core cables with Reinforced Insulation

EN 50382 High Temperature Cable

                                                         A. Conductor            B. Insulation        

Bau

Dirigent
Extra flexible tinned annealed copper wires (red copper only for 150° C core temperature) class 6 according to HD 383

Isolierung
Silicon rubber according to EN 50382-1 (EI 112)

  Electrical & Mechanical Properties

Nominal Voltage 3.6/6 kV
Maximum Conductor Temperature

+120/+150 deg (fixed installation)

Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
  4 x Overall Diameter (D>12mm)

  Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

  Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

  Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070  
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

  FRL-HT-6SURI 3.6/6 kV

Nominalen Querschnitt

(a)

Dirigent

Durch
messer (a)

MIN. Bedeuten, Dicke der Dämmung

Außendurchmesser

Gew
icht

Widerstand der Leiter bei 20 ° C

MIN. Isolationswiderstand

min

max

Verzinnt

Dirigent

Plain

Dirigent

AT +20℃

MIN.

AT +150℃MIN.

mm2

mm

mm

mm

mm

kg/km

Ω/km

Ω/km

MΩ·km

MΩ·km

50

9.2

3.0

15.2

17.8

560

0.393

0.386

340

0.70

70

11.0

3.0

16.9

19.8

770

0.277

0.272

300

0.60

95

12.5

3.0

18.3

21.4

970

0.210

0.206

270

0.55

120

14.2

3.1

20.1

23.5

1200

0.164

0.161

250

0.50

150

15.8

3.1

21.6

25.3

1480

0.132

0.129

220

0.45

185

17.5

3.2

23.4

27.4

1800

0.108

0.106

210

0.40

(a)= For information,indicative only